ready mixed concrete batching plant instrument displays inaccurately
The simple concrete batching plant s performance for weighing, batching control instrument display value is consistent with the set value, but the actual value of the materials mentioned in the display value is greater than or less than. The cause of the fault may be: weighing systems affected by external force; The sensor drift error cause a change in the space between zero or weighing; Damage of sensors.
At this time should eliminate the external force, calibration weighing zero again. Weighing of multiple sensors, want to consider partial load conditions. If partial load, it may be a sensor damage or loose wires, damaged, a sensor and check the cable should be replaced.
We have ready mixed concrete batching plant for sale.If you are interested in any of our products,please contact us withou heasitation.We are looking forward to establish business relationship between us based on our mutual benefits.