WhatsApp / wechat
+86 13598417520
Why bin ingredients will not be involved
One problem of the small concrete batching plant that why bin ingredient will not be involved.
Its performance as a bunker in the process of ingredients not participate in the ingredients, instrumentation and related ingredients indicator light on operation panel, but not action motor or solenoid valve. The failure reason may be: material balance pressure; Related ingredients actuators (motor or solenoid valve) damage; Ac contractor with motor wiring loose, virtual; The damage of the circuit intermediate relay, and related wiring is not normal.
At this time should check the air compressor and gas circuit connection, using a multimeter to check the motor, solenoid valve and related circuit, timely replacement of intermediate relay or contractor. This fault occurs if the ingredients of related indicator light is not bright, instrument display, may be batching control instrument damage or power supply is not normal.
We have mobile cement concrete batching plant for sale.If you are interested in any of our products,please contact us withou heasitation.We are looking forward to establish business relationship between us based on our mutual benefits.
+86 13597417520
+86 (0)371-65621391